<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-19 15-47-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 30 dBuV R-PCE
Pilot RDS Phase Difference
6.1 kHz 2.3 kHz -89 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
14 kHz 37 kHz 8800 0,0114
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,1 dBr -1,24 dBr -0,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 15:47, 19.04.2024
RT
"Zpra r ionu ozho "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 37 kHz MIN: 14 kHz % above 77 kHz: 0,0114 Acquired: 2024/04/19 15:47:43 Total samples: 8800 Equivalent time: 0:07:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: -0,9 dBr MIN: -2,1 dBr AVE: -1,24 dBr % above 0,2 dBr: 0,0 Last value: -1,1 dBr (2024/04/19 15:47:42) 15:34 15:36 15:38 15:40 15:42 15:44 15:46 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality